NEW QUESTION # 35
What is the Fourth Preference Regarding Utility Service?
- A. One circuit from one substation, separate paths
- B. At least four circuits each from different distribution stations but fed via common feeders
- C. At least two circuits from one substation fed via alternative power grid
- D. Two balanced feeds with different voltages derived from a single distribution station
Answer: A
NEW QUESTION # 36
What is the difference between a single bus and a dual bus power distribution system?
- A. Single bus is more reliable than dual bus
- B. Dual bus is more cost-effective than single bus
- C. Single bus has only one power source while dual bus has two independent power sources
- D. Single bus is more flexible and adaptable to changing needs than dual bus
Answer: C
NEW QUESTION # 37
How is the slab and all below grade components prepared in new construction?
- A. with waterproof vinyl tiles
- B. using standard concrete mix without any additives
- C. with a continuously sealed rubberized moisture barrier
- D. only with steel reinforcement bars
Answer: C
NEW QUESTION # 38
What is the function of an emergency generator?
- A. provide backup power to IT equipment only
- B. supply power to the restrooms during a utility outage
- C. back up office lighting
- D. all of the above
Answer: D
NEW QUESTION # 39
What is the distance from the bottom of the access floor to the bottom of the cable tray?
- A. 7 inches
- B. 9 inches
- C. 8 inches
- D. 6 inches
- E. 10 inches
Answer: C
NEW QUESTION # 40
What is a possible downside to customer-owned maintenance holes?
- A. fire risk near data center property
- B. susceptibility to theft or damage by unauthorized personnel
- C. poor aesthetic appearance around facility exterior
- D. leaks leading to water infiltration into data center
Answer: D
NEW QUESTION # 41
What is the recommended range for the high temperature in a data center according to ASHRAE?
- A. 75 degrees
- B. 85 degrees
- C. 90 degrees
- D. 80.6 degrees
- E. 70 degrees
Answer: D
NEW QUESTION # 42
When is a battery room required to have electrolyte spill containment and exhaust systems?
- A. when the potential for outgassing hydrogen exists
- B. When the ceiling suspended load capacity is below 20 pounds per square foot
- C. when the battery weight exceeds 500 pounds
- D. When corrosive fumes are detected in operation room
Answer: A
NEW QUESTION # 43
what can take up to40 percent of overall space in the equipment area?
- A. circulation and support equipment
- B. computer
- C. electrical equipments
- D. all of above
- E. principal loads
- F. redistribution systems
Answer: A
Explanation:
Explanation
NEW QUESTION # 44
How do you calculate thermal load in a data center?
- A. IT Thermal Output + Cooling System + Lighting System + PDU System
- B. IT Thermal Output + PDU System
- C. IT Thermal Output + Lighting System
- D. IT Thermal Output + Cooling System
- E. IT Thermal Output + Cooling System + Lighting System
Answer: A
NEW QUESTION # 45
What three things limit the amount of IT equipment per rack?
- A. staffing availability, security measures, and access points
- B. fire suppression system technology, humidity levels, and network speed
- C. power constraints, cooling constraints and lastly, rack space
- D. sustainability goals, partitioning requirements, and compliance mandates
Answer: C
NEW QUESTION # 46
what are the dimensions of circulation pathways?
- A. 4 feet wide and have clear overhead of 8 feet
- B. None
- C. All
- D. 6feet width, width depends on the layout functionality.
- E. 5 feet width with a height of 7feet.
Answer: A
Explanation:
Explanation
NEW QUESTION # 47
What is the clearance required between AC units?
- A. Min. of 4 ft but recommended 6 ft.
- B. Min. of 6 ft but recommended 8 ft.
- C. Min. of 2 ft but recommended 6 ft.
- D. Min. of 8 ft but recommended 10 ft.
Answer: A
NEW QUESTION # 48
What is the high temperature that must be maintained in a data center according to TIA-942?
- A. 75 degrees
- B. 85 degrees
- C. 77 degrees
- D. 70 degrees
- E. 80 degrees
Answer: C
NEW QUESTION # 49
What is the minimum slab floor to ceiling height recommended?
- A. 15feetminimmum
- B. 16feetminimum
- C. 12feetminimum
- D. 14feetminimum
Answer: A
NEW QUESTION # 50
......
BICSI DCDC-002 is the certification exam for BICSI Data Center Design Consultant (DCDC). It is a globally recognized certification that helps professionals to gain expertise in designing data centers. DCDC-002 exam is designed to validate the skills and knowledge of professionals in data center design, including planning, design, implementation, and maintenance. It is an essential certification for professionals who work in data center design and construction.