Authentic AD01 Dumps - Free PDF Questions to Pass
Guaranteed Accomplishment with Newest Aug-2022 FREE AD01
NEW QUESTION 42
Study the following page in a process:

Calculation stages will write A, B or C to the Output value data item.
What will be the outcome after the page has run?
- A. Data Item Output Value contains "B"
- B. An Internal Exception will be thrown
- C. Data Item Output Value contains "A"
- D. Data Item Output Value contains "C"
Answer: B
NEW QUESTION 43
Exhibit:
The Process is intended to attempt to perform the processing in the recover block, Block 3. a maximum of three times before throwing an exception.
Data Item 'Attempts' is a number data item with an initial value of 0
Data Item "Max Attempts" is a number data item with an initial value of 3 The 'Increment Attempts' calculation stage add 1 to the attempts value and outputs a result to the "Attempts" data item To enable this to work correctly, what is the correct expressions for the Try Again' decision stage?
- A. [Attempts] < [Max]
- B. [Attempts] + 1
- C. [Attempts] > [Max]
- D. [Attempts] = [Max]
Answer: A
NEW QUESTION 44
A process contains only 4 stages Study the following process flow:
The data Item Result' is a number data item with an initial value of 2.
The calculation stage is configured as follows:
Following the execution of the Perform Calculation stage, which of the following is true?
- A. The data item Result will contain 3
- B. None of these statements are correct
- C. The process will throw an exception
- D. The data item Result will contain 5
Answer: A
NEW QUESTION 45
An action called Get Account details' fails with the following exception detail:
Which of the following could cause this exception?
- A. The Read Details action is not connected to another stage so cannot execute.
- B. The Business Object has not been coupled to the application by either launching it or attaching to it.
- C. The Read Details action in the Get Account Details Business Object no longer exists but the Process is attempting to use it.
- D. An internal error always indicates a problem with the Blue Prism product. The Blue Prism support team should be contacted for assistance
Answer: B
Explanation:
Explanation
Reason: This is happening when the application is not attached or launched and user tries to read the action.
Exercise also mentioned in the foundation course. Below snapshot is from the Exception pdf.
NEW QUESTION 46
Which of the following indicates a case in a Work Queue is waiting to be worked?
A)
B)
C)
D)
C
- A. Option B
- B. Option A
- C. Option D
- D. Option C
Answer: D
NEW QUESTION 47
Which of the following Stages can be found Process Studio but NOT Object studio?
- A. Option B
- B. Option A
- C. Option D
- D. Option C
Answer: C
NEW QUESTION 48
Consider the following flow within an Object Studio action:
The developer of this flow found that writing some credentials to the target application sometimes failed with an exception even though the element exists on the screen. He found that simply catching the exception, waiting for 2 seconds and then retrying fixed the problem.
What problems do you see within the flow? (select 2 responses)
- A. A block has not been placed around the Write stage and the Recover stage, meaning the credentials action could be unnecessarily retried if another stage further into this action throws an exception.
- B. There is not a Resume stage following the timeout of the Wait stage
- C. The credentials stage is a read stage not a write stage.
- D. There is a potential for an infinite loop if the 'Credentials' stage keeps throwing an exception for some unforeseen reason.
Answer: A,C
NEW QUESTION 49
Study the following page in a process:
Calculation stages will write A, B or C to the Output value data item.
What will be the outcome after the page has run?
- A. Data Item Output Value contains “B”
- B. An Internal Exception will be thrown
- C. Data Item Output Value contains “A”
- D. Data Item Output Value contains “C”
Answer: C
NEW QUESTION 50
Consider the following flow within an Object Studio action:
The developer of this flow found that writing some credentials to the target application sometimes failed with an exception even though the element exists on the screen. He found that simply catching the exception, waiting for 2 seconds and then retrying fixed the problem.
What problems do you see within the flow? (select 2 responses)
- A. A block has not been placed around the Write stage and the Recover stage, meaning the credentials action could be unnecessarily retried if another stage further into this action throws an exception.
- B. There is not a Resume stage following the timeout of the Wait stage
- C. The credentials stage is a read stage not a write stage.
- D. There is a potential for an infinite loop if the 'Credentials' stage keeps throwing an exception for some unforeseen reason.
Answer: A,C
NEW QUESTION 51
When building a solution to use Tags within a Work Queue, which of the following statements is correct true?
- A. Adding a tag requires an item to be locked
- B. Adding a tag does not require an item to be locked
- C. Adding a tag requires an item to be locked if there are multiple resources working the same queue
Answer: B
NEW QUESTION 52
A screen contains four buttons, Find, Save, Close and New. When the buttons are spied, the attributes are identical except for the Window Text attribute.
The values for the Windows Text attribute are 'Find' for the Find button, 'Save' for the Save button, 'Close' for the Close button and 'New' for the New Button.
The Dynamic Button element has been spied and has the following attributes set:
A navigate stage has been configured to press the Close button:
What additional configuration is required to ensure the Close button is selected by the Navigate stage?
- A. Set the Mouse Button value to 'Close'
- B. It is not possible to select the Close button using the Dynamic Button element because the value is set to
'Find' in the Application Modeller - C. A new element is required with the Window Text value set to 'Close' and the Match Type set to equal
- D. The Params button must be selected and the parameter configured to override the Window Text attribute value to 'Close'
Answer: D
NEW QUESTION 53
When a process is running in Control Room which of the following functions within the process can be accessed from Control Room to request the process to stop?
- A. StopNow()
- B. IsStopRequestec?
- C. Stop()
- D. StopNow?
- E. Stop?
- F. IsStopRequested()
Answer: F
Explanation:
Explanation
Reason: IsStopRequested() function is used for the immediate stop provided by the blueprism (mentioned in the foundation course)
NEW QUESTION 54
Examine the following Blue Prism Process diagram:
The Process contains logic in the 'Control Room Stop Request?' Decision stage, to recognise when a Process Controller has used the 'Request Stop' feature in Control Room, to bring the Process to a controlled stop.
What expression would you use in the 'Control Room Stop Request?' Decision stage, to ensure that the Process recognises that the Control Room 'Request Stop' command has been triggered?
(Remember, Blue Prism expressions are case sensitive)
Answer:
Explanation:
IsStopRequestedenvironmentfunction
Reference:
https://bpdocs.blueprism.com/bp-6-10/en-us/frmControlRoom.htm
NEW QUESTION 55
Which of the following statements about Business Objects is true?
- A. A Business Object is configured in the Studio area of Blue Prism
- B. A Business Object can be exposed to Control Room
- C. It is Blue Prism best practice to include business rules within Business Objects
- D. Logging of individual stages is not configurable in Business Objects
Answer: A
Explanation:
Reason: As the business object is only configure in the Object studio.
Rest all other reasons are failed.
NEW QUESTION 56
Consider the following flow in an object:
Which of the following statements are true?
- A. If during testing in object studio this flow works, no additional wait stages should be added as they will slow the interface down.
- B. There should be an intelligent wart stage after the start stage and after any stage that cause the application we are interfacing with to change
- C. There just needs to be a wait stage after the start stage to correct this action.
- D. There should be a wait stage after every stage in this flow (i.e. after the navigate, read, write stages.
Answer: D
NEW QUESTION 57
Study the process flow below:
The outputs for the Get Next Case are configured below:

What is the correct configuration of the Expression in the “Case-Returned” decision stage?
- A.

- B.

- C.

- D.

Answer: B
NEW QUESTION 58
Consider the following flow within an Object Studio action:
The developer of this flow found that writing some credentials to the target application sometimes failed with an exception even though the element exists on the screen. He found that simply catching the exception, waiting for 2 seconds and then retrying fixed the problem.
What problems do you see within the flow? (select 2 responses)
- A. A block has not been placed around the Write stage and the Recover stage, meaning the credentials action could be unnecessarily retried if another stage further into this action throws an exception.
- B. There is not a Resume stage following the timeout of the Wait stage
- C. The credentials stage is a read stage not a write stage.
- D. There is a potential for an infinite loop if the 'Credentials' stage keeps throwing an exception for some unforeseen reason.
Answer: A,C
NEW QUESTION 59
The data item "Loop Counter" is a number data item and has an initial value of 0. The data item "Max Loops" is a number data item and has an initial value of 10.
The two stages are configured as follows:

How many times will the Loop Again stage be executed when the page is executed?
- A. 0
- B. 1
- C. 2
- D. The loop will be infinite
Answer: D
NEW QUESTION 60
Which of the following can you perform in Control Room? (select all that apply)
- A. Create a Work Queue
- B. Encrypt a Work Queue
- C. Rename a Work Queue
- D. Refresh a Work Queue
Answer: D
NEW QUESTION 61
A screen contains four buttons, Find, Save, Close and New. When the buttons are spied, the attributes are identical except for the Window Text attribute.
The values for the Windows Text attribute are 'Find' for the Find button, 'Save' for the Save button, 'Close' for the Close button and 'New' for the New Button.
The Dynamic Button element has been spied and has the following attributes set:
A navigate stage has been configured to press the Close button:
What additional configuration is required to ensure the Close button is selected by the Navigate stage?
- A. Set the Mouse Button value to 'Close'
- B. A new element is required with the Window Text value set to 'Close' and the Match Type set to equal
- C. It is not possible to select the Close button using the Dynamic Button element because the value is set to 'Find' in the Application Modeller
- D. The Params button must be selected and the parameter configured to override the Window Text attribute value to 'Close'
Answer: D
NEW QUESTION 62
Consider the following process flow from a sub-page of a process:
What is the problem with this sub-page flow?
- A. The sub-page process flow is missing any retry exception handling that should exist where a process calls object actions that interface with an application.
- B. There is nothing wrong with the sub-page flow shown in this image
- C. The exception stage within the flow should be removed and replaced with an End stage that returns the found data item as an output parameter.
- D. For better visibility of the process logic the flow steps shown in the image should be on the main page rather than in a sub-page of the process.
Answer: B
NEW QUESTION 63
......
How to Prepare For Blue Prism Developer AD01 Exam
Preparation Guide for Blue Prism Developer AD01 Exam
Introduction to Blue Prism Developer AD01 Exam
Blue Prism Developer AD01 Exam is related to Blue Prism Accredited Developer Certification. This Blue Prism Accredited Developer AD01 Exam validates the ability to keep sensitive data of session Logs and control room, work queues, creation and administration, process flow through decision, choice stages and sub-pages, correct use of action retrying from a process as per Blue Prism standard template. Object Layer Designers and Blue Prism Developers usually hold or will pursue this certification and you can expect the same job role after completing this Blue Prism Accredited Developer certification.
AD01 Braindumps PDF, Blue Prism AD01 Exam Cram: https://www.dumpstests.com/AD01-latest-test-dumps.html
Use Valid New Free AD01 Exam Dumps & Answers: https://drive.google.com/open?id=1g8kiEXISD-1xTY1TDGn_jaaQrHyohcqn